1 y ·Translate

LED Operating Lamp Free Sample Technical Parameters ModelMXLED500 Illumination锛圠UX)130000-160000锛圓djustable锛?/p> Color Temp锛圞锛?/p>4300卤500 Dimming spot锛坢m锛?/p>100鈥?00 Lighting Depth锛坢m锛?/p>鈮?200 Dimming1-100 Color rendering index CRI鈮?7% Color reduction index Ra鈮?7% LED Bulb Life Span锛坔锛?/p>鈮?0000 Power/Bulb1W/3V Install height锛坢m锛?/p>2800鈥?000 鈻?Characteristic 鈼?Ultra-long LED service life, up to 60000 hours without replacing the lamp beads, 40 times longer than halogen lamp life. At the same brightness, the energy consumption of leds is only 1/10 of that of ordinary incandescent lamps and 1/2 of halogen lamps. 鈼?Imported LED cold light source without infrared radiation, nano-coating radiator, resulting in excellent heat dissipation effect. Light emitting diode was used as light source, no temperature rise, no ultraviolet radiation, no stroboscopic. 鈼?Perfect shadowless lamp effect, scientific radian focusing design, cleverly avoid the doctor's head and shoulder block, to achieve the ideal shadowless effect and super depth lighting. Shadowless lamp maintenance method: 1. Adhere to the daily maintenance and inspection of the shadowless lamp, including the disinfection of the daily lamp handle and the scrubbing of the appearance. It should be noted that if there is an arc shadow, the bulb should be changed. 2. Regular monthly inspection, by cutting off the 220V power supply, to see whether the standby power supply is started, to determine whether the standby power system is normal. 3. The annual maintenance of the shadowless lamp to replace the lamp holder, tighten the power cord connector, lamp working voltage test and check the vertical of the suspension tube and the balance of the suspension system. What are the steps of operation shadowless light debugging: 1. Installation inspection: whether the screws are all in place and tightened during the installation process, and whether all kinds of decorative covers have been covered. 2. Circuit inspection: this is one of the key points of safety inspection, the first is to check whether there is a short circuit or circuit breaker phenomenon in the case of power off, if not, then check whether the power supply is stable, the transformer input voltage is stable and in line with the requirements of the shadow lamp. 3. Balance arm adjustment: when the medical staff adjusts the position of the surgical light, it is necessary to balance the arm system to carry out the force, so it is necessary to check whether the balance arm can be adjusted to the Angle needed by the medical staff and whether it can be forced. 4. Joint flexibility: because it is necessary to adjust the Angle of the headless lamp, the flexibility of the joint is also very important, mainly to adjust the damping screw of the joint. The standard stipulates that the tightness of the damping adjustment is close to 20N or 5Nm in any position to push or rotate the joint.LED Operating Lamp Free Sample website:http://www.mingxumedical.com/o....perating-shadowless-